International Residential Code for One- and Two-family Dwellings |
From inside the book
Results 1-3 of 84
Page 99
... accordance with one of the following : 1. Gypsum board installed with minimum No. 6 screws in accordance with Section R702 . 2. Continuous steel strapping installed in accordance with Figure R505.3 . Steel straps shall be at least 1.5 ...
... accordance with one of the following : 1. Gypsum board installed with minimum No. 6 screws in accordance with Section R702 . 2. Continuous steel strapping installed in accordance with Figure R505.3 . Steel straps shall be at least 1.5 ...
Page 245
... SECTION INSIDE A TRACK SECTION SCREWED AT 24 IN . O.C. THROUGH TOP AND BOTTOM FLANGES FIGURE R804.3.3.1 RIDGE BOARD ... accordance with Figure R804.3 . Roof cantilevers shall be supported by a header in accordance with Section R603.6 or ...
... SECTION INSIDE A TRACK SECTION SCREWED AT 24 IN . O.C. THROUGH TOP AND BOTTOM FLANGES FIGURE R804.3.3.1 RIDGE BOARD ... accordance with Figure R804.3 . Roof cantilevers shall be supported by a header in accordance with Section R603.6 or ...
Page 416
... accordance with Section P3104 . The circuit vent pipe shall not receive the discharge of any soil or waste . P3110.3 Slope and size of horizontal branch . The maximum slope of the vent section of the horizontal branch drain shall be one ...
... accordance with Section P3104 . The circuit vent pipe shall not receive the discharge of any soil or waste . P3110.3 Slope and size of horizontal branch . The maximum slope of the vent section of the horizontal branch drain shall be one ...
Other editions - View all
International Residential Code for One- and Two-Family Dwellings: Turbo Tabs International Code Council No preview available - 2003 |
Common terms and phrases
12 inches accor accordance with Section accordance with Table air admittance valve appliance applied approved ASTM braced wall line braced wall panels ceiling joists clearance combustion air comply concrete conductors connected construction dead load diameter draft hood drain drainage ducts equipment exceed exterior walls FAN NAT FAN fastened feet FIGURE fireplace fixture floor flue furnace grade Ground snow load grout heaters height horizontal installed in accordance insulating concrete form insulation International Building Code joints joists kN/m² less LINTEL listed and labeled located manufacturer's installation instructions masonry material maximum metal mile per hour minimum nail NAT FAN NAT opening outlet permitted piping material pound per square pressure R-value reinforcement roof screws Seismic Design Categories sheathing slope Southern pine space square foot square inch studs thickness tion Type units valve vent connector venting system vertical wall studs wind speed Wood shingles wood structural panel