... reinforcement shall consist of at least two wires of W1.7 spaced not more than 16 inches ( 406 mm ) ; or bond beam reinforcement shall be pro- vided of at least one No. 4 bar spaced not more than 10 feet ( 3048 mm ) . Horizontal ...
... reinforcement shall consist of at least two wires of W1.7 spaced not more than 16 inches ( 406 mm ) ; or bond beam reinforcement shall be pro- vided of at least one No. 4 bar spaced not more than 10 feet ( 3048 mm ) . Horizontal ...
Page 173
... reinforcement of at least 0.0015 times the gross cross - sectional area of masonry . Table R606.11.4.1 provides minimum reinforcing bar sizes for masonry walls . The maximum spacing of hori- zontal reinforcement shall be 24 inches ( 610 ...
... reinforcement of at least 0.0015 times the gross cross - sectional area of masonry . Table R606.11.4.1 provides minimum reinforcing bar sizes for masonry walls . The maximum spacing of hori- zontal reinforcement shall be 24 inches ( 610 ...
Page 193
... reinforcement in accordance with the following : 1. Vertical reinforcement consisting of at least one No. 4 reinforcing bar , extending continuously from sup- port to support , shall be provided at each corner , at each side of each ...
... reinforcement in accordance with the following : 1. Vertical reinforcement consisting of at least one No. 4 reinforcing bar , extending continuously from sup- port to support , shall be provided at each corner , at each side of each ...
Other editions - View all
International Residential Code for One- and Two-Family Dwellings: Turbo Tabs International Code Council No preview available - 2003 |
Common terms and phrases
12 inches accor accordance with Section accordance with Table air admittance valve appliance applied approved ASTM braced wall line braced wall panels ceiling joists clearance combustion air comply concrete conductors connected construction dead load diameter draft hood drain drainage ducts equipment exceed exterior walls FAN NAT FAN fastened feet FIGURE fireplace fixture floor flue furnace grade Ground snow load grout heaters height horizontal installed in accordance insulating concrete form insulation International Building Code joints joists kN/m² less LINTEL listed and labeled located manufacturer's installation instructions masonry material maximum metal mile per hour minimum nail NAT FAN NAT opening outlet permitted piping material pound per square pressure R-value reinforcement roof screws Seismic Design Categories sheathing slope Southern pine space square foot square inch studs thickness tion Type units valve vent connector venting system vertical wall studs wind speed Wood shingles wood structural panel