International Residential Code for One- and Two-family DwellingsThe 2000 International Residential Code brings uniformity to the construction of one- and two-family dwellings and townhouses. A comprehensive code for building design, this book brings together all building, plumbing, mechanical, and fuel gas provisions. It establishes minimum regulations using prescriptive provisions, and is founded on broad-based principles that make possible the use of materials and building designs. |
From inside the book
Results 1-3 of 84
Page 51
... INSULATION R320.1 Insulation . Insulation materials , including facings , such as vapor barriers or breather papers installed within floor- ceiling assemblies , roof - ceiling assemblies , wall assemblies , crawl spaces and attics shall ...
... INSULATION R320.1 Insulation . Insulation materials , including facings , such as vapor barriers or breather papers installed within floor- ceiling assemblies , roof - ceiling assemblies , wall assemblies , crawl spaces and attics shall ...
Page 64
... insulation below gound . Horizontal insulation placed less than 12 inches ( 305 mm ) below the ground surface or that portion of hori- zontal insulation extending outward more than 24 inches ( 610 mm ) from the foundation edge shall be ...
... insulation below gound . Horizontal insulation placed less than 12 inches ( 305 mm ) below the ground surface or that portion of hori- zontal insulation extending outward more than 24 inches ( 610 mm ) from the foundation edge shall be ...
Page 281
... insulation materials installed in framing cavities and / or insulating sheathing applied , and not by framing , drywall , structural sheathing , or exterior siding materials . Insulation separated from the conditioned space by a vented ...
... insulation materials installed in framing cavities and / or insulating sheathing applied , and not by framing , drywall , structural sheathing , or exterior siding materials . Insulation separated from the conditioned space by a vented ...
Contents
AE302 Application for Permit | 3 |
E3509 Bonding | 20 |
P2605 Support | 384 |
Copyright | |
10 other sections not shown
Other editions - View all
Common terms and phrases
12 inches accor accordance with Section accordance with Table air admittance valve appliance applied approved ASTM braced wall line braced wall panels ceiling joists clearance cold-formed steel comply concrete conductors connected construction dead load diameter draft hood drain drainage ducts equipment exceed exterior walls FAN NAT FAN fastened feet Figure fireplace fixture floor flue furnace grade Ground snow load grout heaters height horizontal installed in accordance insulating concrete form insulation International Building Code joints kN/m² length less light-frame construction LINTEL listed and labeled located lumber manufacturer's installation instructions masonry material maximum metal mile per hour minimum nail NAT FAN NAT opening outlet permitted piping material pound per square pressure R-value reinforcement roof screws Seismic Design Categories sheathing slope Southern pine space square foot square inch studs thickness tion Type units valve vent connector venting system vertical wall studs wind speed Wood shingles