Uniform Building CodePacific Coast Building Officials Conference, 1946 - Building laws |
From inside the book
Results 1-3 of 86
Page 166
... Code if axial stresses only existed . F = Bending unit stress that would be permitted by this Code if bending stresses only existed . f , Unit axial stress ( actual ) that is , the total axial stress divided by the area of the member ...
... Code if axial stresses only existed . F = Bending unit stress that would be permitted by this Code if bending stresses only existed . f , Unit axial stress ( actual ) that is , the total axial stress divided by the area of the member ...
Page 255
... Code . ( See Section 105. ) ( c ) Definition . PREFABRICATED ASSEMBLY is a struc- tural unit , the integral parts of which have been built up or assembled prior to incorporation in the building . Sec . 5002. Every approval of a material ...
... Code . ( See Section 105. ) ( c ) Definition . PREFABRICATED ASSEMBLY is a struc- tural unit , the integral parts of which have been built up or assembled prior to incorporation in the building . Sec . 5002. Every approval of a material ...
Page 271
... Code where provisions covering the and X - ray handling and storage of photographic and X - ray nitrocellulose Films films are desired : Sec . 4801. The provisions of this Chapter do not apply to : Classes of 1. Film for amateur ...
... Code where provisions covering the and X - ray handling and storage of photographic and X - ray nitrocellulose Films films are desired : Sec . 4801. The provisions of this Chapter do not apply to : Classes of 1. Film for amateur ...
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood