Uniform Building CodePacific Coast Building Officials Conference, 1946 - Building laws |
From inside the book
Results 1-3 of 5
Page 34
... continued , if such use or occupancy was legal at the time of the passage of this Code , provided such continued use is not dangerous to life . Sec . 503. ( a ) General . When a building is used for more than one occupancy purpose each ...
... continued , if such use or occupancy was legal at the time of the passage of this Code , provided such continued use is not dangerous to life . Sec . 503. ( a ) General . When a building is used for more than one occupancy purpose each ...
Page 117
... continued at atmospheric pressure for 16 hours , making total soaking period of 24 hours . The wet samples shall then be dried in a room at a relative humidity of 30 per cent or less and a tem- perature of 70 to 85 degrees Fahrenheit ...
... continued at atmospheric pressure for 16 hours , making total soaking period of 24 hours . The wet samples shall then be dried in a room at a relative humidity of 30 per cent or less and a tem- perature of 70 to 85 degrees Fahrenheit ...
Page 234
... ( Continued ) Other. TABLE NO . 43 - B - Rated Fire - Resistive Periods for Various Walls and Partitions MATERIAL CONSTRUCTION Minimum Finished Thickness face to face ( including plaster where mentioned ) in inches 4 - hr . 3 - hr . 2 - hr ...
... ( Continued ) Other. TABLE NO . 43 - B - Rated Fire - Resistive Periods for Various Walls and Partitions MATERIAL CONSTRUCTION Minimum Finished Thickness face to face ( including plaster where mentioned ) in inches 4 - hr . 3 - hr . 2 - hr ...
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood