... Division 1. Any assembly building with a stage and a seating capacity of less than 1000 in any one room . Division 2. Any assembly building without a stage and a seating capacity of 300 or more in any one room . Division 3. Any assembly ...
... Division 1. Any assembly building with a stage and a seating capacity of less than 1000 in any one room . Division 2. Any assembly building without a stage and a seating capacity of 300 or more in any one room . Division 3. Any assembly ...
Page 43
... Division 4 structures to be re - inspected at least once every six months . Sec . 703. All buildings housing Group B occupancies shall Location on front directly upon at least one public street , not less than Property twenty feet ( 20 ...
... Division 4 structures to be re - inspected at least once every six months . Sec . 703. All buildings housing Group B occupancies shall Location on front directly upon at least one public street , not less than Property twenty feet ( 20 ...
Page 47
... Division 2 : Nurseries for the care of children under six years of age . Hospitals , sanitariums , and similar ... Division 1 occupancies shall be of Type I construction throughout . Division 2 occupancies shall be of not less than one ...
... Division 2 : Nurseries for the care of children under six years of age . Hospitals , sanitariums , and similar ... Division 1 occupancies shall be of Type I construction throughout . Division 2 occupancies shall be of not less than one ...
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood