Page 42
... occupancies shall be : Division 1. Any assembly building with a stage and a seating capacity of less than 1000 in ... 3. Any assembly building without a stage and with no room having a seating capacity of more than 300 . Division 4 ...
... occupancies shall be : Division 1. Any assembly building with a stage and a seating capacity of less than 1000 in ... 3. Any assembly building without a stage and with no room having a seating capacity of more than 300 . Division 4 ...
Page 56
... occupancies shall be : Division 1. Homes for the aged , orphanages , homes ... ( 3 ' ) from adjacent property lines , shall have no openings therein , shall ... occupancies on the property shall meet the requirements of any State laws which ...
... occupancies shall be : Division 1. Homes for the aged , orphanages , homes ... ( 3 ' ) from adjacent property lines , shall have no openings therein , shall ... occupancies on the property shall meet the requirements of any State laws which ...
Page 60
... occupancy group other than Group J that it most nearly resembles . Sec . 1503. All exterior walls , or parts of walls , except on street fronts , of Division 1 , Group J occupancies , which are less than three feet ( 3 ' ) from adjacent ...
... occupancy group other than Group J that it most nearly resembles . Sec . 1503. All exterior walls , or parts of walls , except on street fronts , of Division 1 , Group J occupancies , which are less than three feet ( 3 ' ) from adjacent ...
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood