Page 6
... Group B Occupancies 42 Group B Occupancies Defined Construction , Height and Area Allowable 703. Location on ... E Occupancies 49 Group E Occupancies Defined Construction , Height and Area Allowable Location on Property Exit Facilities ...
... Group B Occupancies 42 Group B Occupancies Defined Construction , Height and Area Allowable 703. Location on ... E Occupancies 49 Group E Occupancies Defined Construction , Height and Area Allowable Location on Property Exit Facilities ...
Page 48
... plant which burns gas as fuel shall be separated from the rest of the building by not less than an " Ordinary Occupancy Separation . ” CHAPTER 10 - REQUIREMENTS FOR GROUP E OCCUPANCIES Group E 48 Section 908 UNIFORM BUILDING CODE.
... plant which burns gas as fuel shall be separated from the rest of the building by not less than an " Ordinary Occupancy Separation . ” CHAPTER 10 - REQUIREMENTS FOR GROUP E OCCUPANCIES Group E 48 Section 908 UNIFORM BUILDING CODE.
Page 49
... GROUP E OCCUPANCIES Group E Sec . 1001. Group E occupancies shall be : Public garages , paint or petroleum storage , dry cleaning Occupancies plants using flammable liquids , paint shops and spray painting Defined rooms and shops ...
... GROUP E OCCUPANCIES Group E Sec . 1001. Group E occupancies shall be : Public garages , paint or petroleum storage , dry cleaning Occupancies plants using flammable liquids , paint shops and spray painting Defined rooms and shops ...
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood