Uniform Building CodePacific Coast Building Officials Conference, 1946 - Building laws |
From inside the book
Results 1-3 of 72
Page 7
Fire - Extinguishing Apparatus 1008 . Special Hazards CHAPTER 11 .
Requirements for Group F Occupancies 52 SEC . 1101 . Group F Occupancies
Defined 1102 . Construction , Height and Area Allowable 1103 . Location on
Property 1104 .
Fire - Extinguishing Apparatus 1008 . Special Hazards CHAPTER 11 .
Requirements for Group F Occupancies 52 SEC . 1101 . Group F Occupancies
Defined 1102 . Construction , Height and Area Allowable 1103 . Location on
Property 1104 .
Page 27
In addition to the inspections to be Special made as specified in Section 304 , the
owner or his agent shall Supervision employ a special inspector during
construction on the following types of work : 1 . CONCRETE : On concrete work
when the ...
In addition to the inspections to be Special made as specified in Section 304 , the
owner or his agent shall Supervision employ a special inspector during
construction on the following types of work : 1 . CONCRETE : On concrete work
when the ...
Page 132
113 Flexure : fc Extreme fiber stress in compression Shear : 0 Beams with no web
reinforcement and without special anchorage of longitudinal steel Beams with no
web reinforcement , but with special anchorage of longitudinal steel Beams ...
113 Flexure : fc Extreme fiber stress in compression Shear : 0 Beams with no web
reinforcement and without special anchorage of longitudinal steel Beams with no
web reinforcement , but with special anchorage of longitudinal steel Beams ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Page | 11 |
FireProtection of Structural Members 2210 Floor Construction | 12 |
Special Hazards | 13 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent allowable applied approved bars beams bearing bending bolts Building Official building or structure carry ceiling cement cent Chapter Class coat Code column compression concrete conform connections construction covering Definition designed diameter direction distance doors edge enclosures exceed exit extend exterior walls face feet fire fire-resistive construction floor foot foundation four frame grade Group gypsum height horizontal inches installed interior joints joists lath least length less load located masonry materials metal occupancy one-half openings panel partitions permit piles pipe placed plaster plate portion pounds protected reinforcement resistance rivets roof Separation shear side slab solid space span Special specified specified in Section square inch Standard steel story strength stress strip structural surface Table tests thickness tion Type unit values vent Ventilation vertical walls width wire wood