Uniform Building CodePacific Coast Building Officials Conference, 1946 - Building laws |
From inside the book
Results 1-3 of 42
Page 68
... Stairs and stair platforms shall be constructed of reinforced concrete , iron or steel with treads and risers of con- crete , iron or steel . Brick , marble , tile or other hard incom- bustible materials may be used for the finish of ...
... Stairs and stair platforms shall be constructed of reinforced concrete , iron or steel with treads and risers of con- crete , iron or steel . Brick , marble , tile or other hard incom- bustible materials may be used for the finish of ...
Page 205
... stairs shall be not more than two feet ( 2 ′ ) narrower than the required width of such corridors , halls , or stairs . Exit doors in schoolrooms shall swing in the direction of egress . ( f ) Corridor Dead End . There shall be no dead ...
... stairs shall be not more than two feet ( 2 ′ ) narrower than the required width of such corridors , halls , or stairs . Exit doors in schoolrooms shall swing in the direction of egress . ( f ) Corridor Dead End . There shall be no dead ...
Page 288
... STAIRS ) ELECTRIC WELDING ( see WELDING ) ELEVATOR SHAFTS ( see VERTICAL OPENINGS ) EMERGENCY Controls for ... STAIRS AND EXITS ) For elevators For stairs and ramps .. Miscellaneous openings Required , when ... Smokeproof enclosure ...
... STAIRS ) ELECTRIC WELDING ( see WELDING ) ELEVATOR SHAFTS ( see VERTICAL OPENINGS ) EMERGENCY Controls for ... STAIRS AND EXITS ) For elevators For stairs and ramps .. Miscellaneous openings Required , when ... Smokeproof enclosure ...
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood