Uniform Building CodePacific Coast Building Officials Conference, 1946 - Building laws |
From inside the book
Results 1-3 of 44
Page 87
Other solid masonry units of clay or shale shall meet the requirements for the
physical properties of brick as specified in A . S . T . M . “ Standard Specifications
for Building Brick ( Made from Clay or Shale ) , ” ( C62 - 44 ) . ( b ) Concrete
Masonry ...
Other solid masonry units of clay or shale shall meet the requirements for the
physical properties of brick as specified in A . S . T . M . “ Standard Specifications
for Building Brick ( Made from Clay or Shale ) , ” ( C62 - 44 ) . ( b ) Concrete
Masonry ...
Page 246
Sand shall be washed sand conforming to A . S . T . M . “ Standard Specifications
for Sand for Use in Plaster , " ( C35 - 39 ) ; except that when used with portland
cement for scratch coat plastering , the amount of sand retained on a No . 8 sieve
...
Sand shall be washed sand conforming to A . S . T . M . “ Standard Specifications
for Sand for Use in Plaster , " ( C35 - 39 ) ; except that when used with portland
cement for scratch coat plastering , the amount of sand retained on a No . 8 sieve
...
Page 257
The following list includes all of the specifications , suggested ordinances and
regulations referred to in this Code : NATIONAL STANDARD SPECIFICATIONS
REFERRED TO IN CHAPTERS 1 TO 51 Uniform Building Code Author ...
The following list includes all of the specifications , suggested ordinances and
regulations referred to in this Code : NATIONAL STANDARD SPECIFICATIONS
REFERRED TO IN CHAPTERS 1 TO 51 Uniform Building Code Author ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Page | 11 |
FireProtection of Structural Members 2210 Floor Construction | 12 |
Special Hazards | 13 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent allowable applied approved bars beams bearing bending bolts Building Official building or structure carry ceiling cement cent Chapter Class coat Code column compression concrete conform connections construction covering Definition designed diameter direction distance doors edge enclosures exceed exit extend exterior walls face feet fire fire-resistive construction floor foot foundation four frame grade Group gypsum height horizontal inches installed interior joints joists lath least length less load located masonry materials metal occupancy one-half openings panel partitions permit piles pipe placed plaster plate portion pounds protected reinforcement resistance rivets roof Separation shear side slab solid space span Special specified specified in Section square inch Standard steel story strength stress strip structural surface Table tests thickness tion Type unit values vent Ventilation vertical walls width wire wood