Uniform Building CodePacific Coast Building Officials Conference, 1946 - Building laws |
From inside the book
Results 1-3 of 82
Page 62
... Type IV construction in excess of one thou- sand square feet ( 1000 sq . ft . ) in floor area nor any building of Type V construction already erected in Fire Zone No. 1 shall hereafter be altered , raised , enlarged , added to or moved ...
... Type IV construction in excess of one thou- sand square feet ( 1000 sq . ft . ) in floor area nor any building of Type V construction already erected in Fire Zone No. 1 shall hereafter be altered , raised , enlarged , added to or moved ...
Page 64
... Type of Construction , it shall comply with all of the requirements for that Type of Construction , as specified in this Code . No building or portion thereof shall be required to conform to the details of a Type of Construction higher ...
... Type of Construction , it shall comply with all of the requirements for that Type of Construction , as specified in this Code . No building or portion thereof shall be required to conform to the details of a Type of Construction higher ...
Page 79
... Type I , II , III or IV construction shall be considered to be of Type V. Sec . 2202. Type V buildings shall not exceed a height of Height thirty - eight feet ( 38 ' ) ; provided that the height of a building Allowable erected on ...
... Type I , II , III or IV construction shall be considered to be of Type V. Sec . 2202. Type V buildings shall not exceed a height of Height thirty - eight feet ( 38 ' ) ; provided that the height of a building Allowable erected on ...
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood