Uniform Building CodePacific Coast Building Officials Conference, 1946 - Building laws |
From inside the book
Results 1-3 of 86
Page 62
... Types of Construction as defined in this Code and shall meet the requirements of this Section . ( b ) Limitation of Types of Construction . Buildings or struc- tures of Type IV or Type V construction having an area greater than seventy ...
... Types of Construction as defined in this Code and shall meet the requirements of this Section . ( b ) Limitation of Types of Construction . Buildings or struc- tures of Type IV or Type V construction having an area greater than seventy ...
Page 64
Pacific Coast Building Officials Conference, International Conference of Building Officials. General Classification by Types of Construction PART V REQUIREMENTS BASED ON TYPES OF CONSTRUCTION - CHAPTER 17 CLASSIFICATION OF ALL BUILDINGS BY ...
Pacific Coast Building Officials Conference, International Conference of Building Officials. General Classification by Types of Construction PART V REQUIREMENTS BASED ON TYPES OF CONSTRUCTION - CHAPTER 17 CLASSIFICATION OF ALL BUILDINGS BY ...
Page 308
... TYPES OF CONSTRUCTION ) Fire - protection of ( see TYPES OF CONSTRUCTION ) .. Classification of buildings Combustible materials regulated . Cornices Enclosure of vertical openings Exterior openings - protection required .505 , 506 ...
... TYPES OF CONSTRUCTION ) Fire - protection of ( see TYPES OF CONSTRUCTION ) .. Classification of buildings Combustible materials regulated . Cornices Enclosure of vertical openings Exterior openings - protection required .505 , 506 ...
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood