Not more than 25 per cent of the roof covering of any building or structure shall
be replaced in any 12 - month period unless the new roof covering is made to
conform to the requirements of this Code for new buildings or structures .
Not more than 25 per cent of the roof covering of any building or structure shall
be replaced in any 12 - month period unless the new roof covering is made to
conform to the requirements of this Code for new buildings or structures .
Page 30
BUILDING is any structure built for the support , shelter , or enclosure of persons ,
animals , chattels , or property of any kind . BUILDING - EXISTING BUILDING is a
building erected prior to the adoption of this Code , or one for which a legal ...
BUILDING is any structure built for the support , shelter , or enclosure of persons ,
animals , chattels , or property of any kind . BUILDING - EXISTING BUILDING is a
building erected prior to the adoption of this Code , or one for which a legal ...
Page 34
International Conference of Building Officials, Pacific Coast Building Officials
Conference. Occupancy ... Chango in Use Mixed Occupancy ori ing B ( c ) Types
of Occupancy Separation 34 Sections 501 - 503 UNIFORM BUILDING CODE.
International Conference of Building Officials, Pacific Coast Building Officials
Conference. Occupancy ... Chango in Use Mixed Occupancy ori ing B ( c ) Types
of Occupancy Separation 34 Sections 501 - 503 UNIFORM BUILDING CODE.
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Page | 11 |
FireProtection of Structural Members 2210 Floor Construction | 12 |
Special Hazards | 13 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
additional adjacent allowable applied approved bars beams bearing bolts Building Official building or structure ceiling cement cent Class Code column compression concrete conform connections construction covering Definition designed diameter distance doors Enclosure exceed exit extend exterior walls face feet fire fire-resistive construction floor foot foundation four frame grade Group gypsum height horizontal inches inspection installed interior joints joists lath least length less Light limits live load located masonry materials metal occupancy one-half openings panel partitions permit pipe placed plaster portion pounds protected regulating reinforcement resistance rivets roof Separation shear side slab solid space Special specified specified in Chapter specified in Section square Standard steel storage story street strength stress Table tests thereof thickness tion Type unit values vent Ventilation vertical walls width wire wood