Uniform Building CodePacific Coast Building Officials Conference, 1946 - Building laws |
From inside the book
Results 1-3 of 37
Page 61
... Zones . " Whenever in such ordinance creating and establishing fire zones , reference is made to any fire zone , it shall be construed to mean one of the three fire zones desig- nated and referred to in this Chapter . ( b ) Buildings ...
... Zones . " Whenever in such ordinance creating and establishing fire zones , reference is made to any fire zone , it shall be construed to mean one of the three fire zones desig- nated and referred to in this Chapter . ( b ) Buildings ...
Page 62
... Zone No. 1 . No building of Type IV construction in excess of one thou- sand square feet ( 1000 sq . ft . ) in floor area nor any building of Type V construction ... Zone No 1 Restrictions in Fire Zone No 2 Restrictions in Fire Zone No 3.
... Zone No. 1 . No building of Type IV construction in excess of one thou- sand square feet ( 1000 sq . ft . ) in floor area nor any building of Type V construction ... Zone No 1 Restrictions in Fire Zone No 2 Restrictions in Fire Zone No 3.
Page 265
... zones . The values given " C " are minimum and should be adopted in locations not subject to frequent seismic dis- turbances as shown in Zone 1. For locations in Zone 2 , " C " should be doubled . For locations in Zone 3 , " C " should ...
... zones . The values given " C " are minimum and should be adopted in locations not subject to frequent seismic dis- turbances as shown in Zone 1. For locations in Zone 2 , " C " should be doubled . For locations in Zone 3 , " C " should ...
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood