... accordance with Chapter 24 , Chapter 26 or Chapter 27. All walls shall be thoroughly and effectively braced ; and effectively fire - stopped at all floor and ceiling levels with incombustible materials . All steel studs shall be ...
... accordance with Chapter 24 , Chapter 26 or Chapter 27. All walls shall be thoroughly and effectively braced ; and effectively fire - stopped at all floor and ceiling levels with incombustible materials . All steel studs shall be ...
Page 108
... accordance with the principles and recommended safe loads set forth in the " Wood Hand- book , " U. S. Department of Agriculture , 1940 . Safe loads and design practice for types of connectors not mentioned or fully covered by the above ...
... accordance with the principles and recommended safe loads set forth in the " Wood Hand- book , " U. S. Department of Agriculture , 1940 . Safe loads and design practice for types of connectors not mentioned or fully covered by the above ...
Page 250
... accordance with the following procedure : 1. Gypsum or Hardwall Plaster . The first coat , for three- coat work , shall be mixed in the proportion of one part of gyp- sum or hardwall plaster to not more than two parts of sand by weight ...
... accordance with the following procedure : 1. Gypsum or Hardwall Plaster . The first coat , for three- coat work , shall be mixed in the proportion of one part of gyp- sum or hardwall plaster to not more than two parts of sand by weight ...
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood