Uniform Building CodePacific Coast Building Officials Conference, 1946 - Building laws |
From inside the book
Results 1-3 of 32
Page 45
... accordance with Chapter 39 . The provisions of Section 1813 shall not apply to openings in buildings not more than three stories high when such openings are not less than thirty feet ( 30 ' ) from adjacent property lines and not less ...
... accordance with Chapter 39 . The provisions of Section 1813 shall not apply to openings in buildings not more than three stories high when such openings are not less than thirty feet ( 30 ' ) from adjacent property lines and not less ...
Page 77
... Section 507 for additional height limitations . Sec . 2103. The floor area ... accordance with Chapter 24 , Chapter 26 or Chapter 27. All walls shall be ... accordance with Chapter 27 . All roof and floor loads shall be transmitted to the ...
... Section 507 for additional height limitations . Sec . 2103. The floor area ... accordance with Chapter 24 , Chapter 26 or Chapter 27. All walls shall be ... accordance with Chapter 27 . All roof and floor loads shall be transmitted to the ...
Page 154
... accordance with Section 2613 and Table No. 26 - B . The base of the metal sec- tion shall be designed to transfer the load from the entire com- posite column to the footing , or it may be designed to trans- fer the load from the metal ...
... accordance with Section 2613 and Table No. 26 - B . The base of the metal sec- tion shall be designed to transfer the load from the entire com- posite column to the footing , or it may be designed to trans- fer the load from the metal ...
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood