... adjacent ground level . Exterior walls or parts of walls , except on street fronts , which are less than five feet ( 5 ′ ) from adjacent property lines shall have no openings therein . Openings in exterior walls , ex- cept on street ...
... adjacent ground level . Exterior walls or parts of walls , except on street fronts , which are less than five feet ( 5 ′ ) from adjacent property lines shall have no openings therein . Openings in exterior walls , ex- cept on street ...
Page 43
... adjacent property lines , except street fronts , shall be of not less than two - hour fire - resistive construction . Exception : When any portion of a Division 4 occupancy is less than ten feet ( 10 ' ) from adjacent property lines ...
... adjacent property lines , except street fronts , shall be of not less than two - hour fire - resistive construction . Exception : When any portion of a Division 4 occupancy is less than ten feet ( 10 ' ) from adjacent property lines ...
Page 45
... adjacent property lines shall have no openings therein and shall be of not less than four - hour fire - resistive construction . Walls which are three feet ( 3 ' ) or more but less than ten feet ( 10 ' ) from adjacent property lines ...
... adjacent property lines shall have no openings therein and shall be of not less than four - hour fire - resistive construction . Walls which are three feet ( 3 ' ) or more but less than ten feet ( 10 ' ) from adjacent property lines ...
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood