Uniform Building CodePacific Coast Building Officials Conference, 1946 - Building laws |
From inside the book
Results 1-3 of 37
Page 251
... applied . Sec . 4708. ( a ) Base Coats . 1. Gypsum Plaster . The Interior scratch coat shall be applied with sufficient material and pres- Plastering : sure to form a full key or bond . Application of Plaster For two - coat work it ...
... applied . Sec . 4708. ( a ) Base Coats . 1. Gypsum Plaster . The Interior scratch coat shall be applied with sufficient material and pres- Plastering : sure to form a full key or bond . Application of Plaster For two - coat work it ...
Page 253
... applied to con- crete or masonry , and except as otherwise provided for pneu- matically applied plaster , exterior cement plastering materials shall be mixed by machine methods for not less than two min- utes , and shall be applied in ...
... applied to con- crete or masonry , and except as otherwise provided for pneu- matically applied plaster , exterior cement plastering materials shall be mixed by machine methods for not less than two min- utes , and shall be applied in ...
Page 262
... applied to concrete or masonry , such plaster shall be applied in not less than two coats to a minimum total thickness of seven - eighths inch ( % " ) . The first coat shall be rodded as specified in Subsection ( 2 ) for the second coat ...
... applied to concrete or masonry , such plaster shall be applied in not less than two coats to a minimum total thickness of seven - eighths inch ( % " ) . The first coat shall be rodded as specified in Subsection ( 2 ) for the second coat ...
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood