Uniform Building CodePacific Coast Building Officials Conference, 1946 - Building laws |
From inside the book
Results 1-3 of 32
Page 19
... building or structure and complying with the requirements for new buildings or structures may be made to such building or struc- ture within any 12 - month period without making the entire building or structure comply . The new construction ...
... building or structure and complying with the requirements for new buildings or structures may be made to such building or struc- ture within any 12 - month period without making the entire building or structure comply . The new construction ...
Page 20
... building or structure , which are non - structural and do not affect any member or part of the building or structure having required fire resistance , may be made with the same materials of which the building or structure is constructed ...
... building or structure , which are non - structural and do not affect any member or part of the building or structure having required fire resistance , may be made with the same materials of which the building or structure is constructed ...
Page 61
... Buildings . Any building or structure moved within or into any Fire Zone shall be made to comply with all the requirements for new buildings in that Fire Zone . ( d ) Temporary Buildings . Temporary buildings such as re- viewing stands ...
... Buildings . Any building or structure moved within or into any Fire Zone shall be made to comply with all the requirements for new buildings in that Fire Zone . ( d ) Temporary Buildings . Temporary buildings such as re- viewing stands ...
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood