Uniform Building CodePacific Coast Building Officials Conference, 1946 - Building laws |
From inside the book
Results 1-3 of 45
Page 30
... ceiling , which is partly below and partly above grade ( as defined in this Section ) , but so located that the vertical distance from grade to the floor below is less than the vertical distance from grade to ceiling . ( See " Story ...
... ceiling , which is partly below and partly above grade ( as defined in this Section ) , but so located that the vertical distance from grade to the floor below is less than the vertical distance from grade to ceiling . ( See " Story ...
Page 58
... Ceiling Heights . Every room required to have windows by Subsection ( a ) shall have a ceiling height of not less than seven feet six inches ( 7 ′ 6 ′′ ) in at least 50 per cent of its required area . Rooms used for living , eating , or ...
... Ceiling Heights . Every room required to have windows by Subsection ( a ) shall have a ceiling height of not less than seven feet six inches ( 7 ′ 6 ′′ ) in at least 50 per cent of its required area . Rooms used for living , eating , or ...
Page 248
... CEILINGS Wire Lath 2.48 16 " 12 " Flat Expanded 2.5 16 " 0 Flat Expanded 3.4 16 " 16 " Flat Rib 2.75 16 " 16 " Flat Rib 3.4 24 " 24 " 3/8 " Rib 3.4 24 " 24 " Sheet Lath 4.5 24 " 24 " TABLE NO . 47 - B - SIZES OF MAIN RUNNERS IN ...
... CEILINGS Wire Lath 2.48 16 " 12 " Flat Expanded 2.5 16 " 0 Flat Expanded 3.4 16 " 16 " Flat Rib 2.75 16 " 16 " Flat Rib 3.4 24 " 24 " 3/8 " Rib 3.4 24 " 24 " Sheet Lath 4.5 24 " 24 " TABLE NO . 47 - B - SIZES OF MAIN RUNNERS IN ...
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood