Uniform Building CodePacific Coast Building Officials Conference, 1946 - Building laws |
From inside the book
Results 1-3 of 34
Page 250
of lime putty or 450 pounds of hydrated lime , 150 pounds of Keene ' s cement
and four pounds of fiber to one cubic yard ( 1 cu . yd . ) of sand . 4 . Portland
Cement Plaster . For three - coat work , the first two coats shall be as required for
the ...
of lime putty or 450 pounds of hydrated lime , 150 pounds of Keene ' s cement
and four pounds of fiber to one cubic yard ( 1 cu . yd . ) of sand . 4 . Portland
Cement Plaster . For three - coat work , the first two coats shall be as required for
the ...
Page 251
A gauged cement plaster mixed in proportion of one part portland cement to not
more than two and one - half parts of lime putty and not more than four parts of
sand by volume . 3 . Smooth white finish , mixed in the proportion of not less than
...
A gauged cement plaster mixed in proportion of one part portland cement to not
more than two and one - half parts of lime putty and not more than four parts of
sand by volume . 3 . Smooth white finish , mixed in the proportion of not less than
...
Page 253
47 - F _ EXTERIOR PORTLAND CEMENT PLASTER MAXIMUM VOLUME OF
MINISAND PER MUM VOLUME PERIOD OF MINIMUM | MOIST CEMENT |
THICKNESS CURING MINIMUM INTERVAL BEFORE APPLICATION OF
SUCCEEDING ...
47 - F _ EXTERIOR PORTLAND CEMENT PLASTER MAXIMUM VOLUME OF
MINISAND PER MUM VOLUME PERIOD OF MINIMUM | MOIST CEMENT |
THICKNESS CURING MINIMUM INTERVAL BEFORE APPLICATION OF
SUCCEEDING ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Page | 11 |
FireProtection of Structural Members 2210 Floor Construction | 12 |
Special Hazards | 13 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent allowable applied approved bars beams bearing bending bolts Building Official building or structure carry ceiling cement cent Chapter Class coat Code column compression concrete conform connections construction covering Definition designed diameter direction distance doors edge enclosures exceed exit extend exterior walls face feet fire fire-resistive construction floor foot foundation four frame grade Group gypsum height horizontal inches installed interior joints joists lath least length less load located masonry materials metal occupancy one-half openings panel partitions permit piles pipe placed plaster plate portion pounds protected reinforcement resistance rivets roof Separation shear side slab solid space span Special specified specified in Section square inch Standard steel story strength stress strip structural surface Table tests thickness tion Type unit values vent Ventilation vertical walls width wire wood