Uniform Building CodePacific Coast Building Officials Conference, 1946 - Building laws |
From inside the book
Results 1-3 of 34
Page 250
... cement and four pounds of fiber to one cubic yard ( 1 cu . yd . ) of sand . 4. Portland Cement Plaster . For three - coat work , the first two coats shall be as required for the first two coats of exterior work . ( b ) Finish Coats for ...
... cement and four pounds of fiber to one cubic yard ( 1 cu . yd . ) of sand . 4. Portland Cement Plaster . For three - coat work , the first two coats shall be as required for the first two coats of exterior work . ( b ) Finish Coats for ...
Page 251
... cement plaster mixed in proportion of one part portland cement to not more than two and one - half parts of lime putty and not more than four parts of sand by volume . 3. Smooth white finish , mixed in the proportion of not less than ...
... cement plaster mixed in proportion of one part portland cement to not more than two and one - half parts of lime putty and not more than four parts of sand by volume . 3. Smooth white finish , mixed in the proportion of not less than ...
Page 253
... CEMENT PLASTER COAT CEMENT MAXIMUM VOLUME OF SAND PER VOLUME OF MINIMUM THICKNESS MINI- MINIMUM INTERVAL BEFORE MUM APPLICATION PERIOD OF MOIST SUCCEEDING CURING COAT First or scratch 32 Second or brown 42 1/2 " * ( 1st & 2nd coats ) 3 ...
... CEMENT PLASTER COAT CEMENT MAXIMUM VOLUME OF SAND PER VOLUME OF MINIMUM THICKNESS MINI- MINIMUM INTERVAL BEFORE MUM APPLICATION PERIOD OF MOIST SUCCEEDING CURING COAT First or scratch 32 Second or brown 42 1/2 " * ( 1st & 2nd coats ) 3 ...
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood