Uniform Building CodePacific Coast Building Officials Conference, 1946 - Building laws |
From inside the book
Results 1-3 of 28
Page 13
Chimneys , Vents and Fireplaces . . . . . . . . . . 210 SEC . 3701 . General 3702 .
Chimneys 3703 . Masonry Chimneys 3704 . Terra Cotta Chimneys 3705 . Metal
Smokestacks 3706 . Smoke Pipes 3707 . Fireplaces 3708 . Gas Vents 3709 .
Chimneys , Vents and Fireplaces . . . . . . . . . . 210 SEC . 3701 . General 3702 .
Chimneys 3703 . Masonry Chimneys 3704 . Terra Cotta Chimneys 3705 . Metal
Smokestacks 3706 . Smoke Pipes 3707 . Fireplaces 3708 . Gas Vents 3709 .
Page 210
CHAPTER 37 – CHIMNEYS , VENTS AND FIREPLACES General Sec . 3701 . ( a
) Scope . Chimneys , fireplaces , flues and vents carrying products of combusion ,
and their connections , shall conform to the requirements of this chapter .
CHAPTER 37 – CHIMNEYS , VENTS AND FIREPLACES General Sec . 3701 . ( a
) Scope . Chimneys , fireplaces , flues and vents carrying products of combusion ,
and their connections , shall conform to the requirements of this chapter .
Page 274
When a chimney with a cross - sectional area over 50 per cent larger than the
cross - sectional area of the vent connections to the chimney , is used as a vent ,
the chimney shall contain a gas vent as specified in Section 3708 or a terra cotta
...
When a chimney with a cross - sectional area over 50 per cent larger than the
cross - sectional area of the vent connections to the chimney , is used as a vent ,
the chimney shall contain a gas vent as specified in Section 3708 or a terra cotta
...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Page | 11 |
FireProtection of Structural Members 2210 Floor Construction | 12 |
Special Hazards | 13 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
additional adjacent allowable applied approved bars beams bearing bolts Building Official building or structure ceiling cement cent Class Code column compression concrete conform connections construction covering Definition designed diameter distance doors Enclosure exceed exit extend exterior walls face feet fire fire-resistive construction floor foot foundation four frame grade Group gypsum height horizontal inches inspection installed interior joints joists lath least length less Light limits live load located masonry materials metal occupancy one-half openings panel partitions permit pipe placed plaster portion pounds protected regulating reinforcement resistance rivets roof Separation shear side slab solid space Special specified specified in Chapter specified in Section square Standard steel storage story street strength stress Table tests thereof thickness tion Type unit values vent Ventilation vertical walls width wire wood