... Chimneys 3703 . 3704 . Masonry Chimneys Terra Cotta Chimneys 3705. Metal Smokestacks 3706. Smoke Pipes 3707 . Fireplaces 3708 . Gas Vents 3709 . 3710 . CHAPTER 38 . SEC . 3801 . 3802 . Protection of Combustible Construction Incinerators ...
... Chimneys 3703 . 3704 . Masonry Chimneys Terra Cotta Chimneys 3705. Metal Smokestacks 3706. Smoke Pipes 3707 . Fireplaces 3708 . Gas Vents 3709 . 3710 . CHAPTER 38 . SEC . 3801 . 3802 . Protection of Combustible Construction Incinerators ...
Page 210
... CHIMNEYS , VENTS AND FIREPLACES Sec . 3701. ( a ) Scope . Chimneys , fireplaces , flues and vents carrying products of combusion , and their connections , shall conform to the requirements of this chapter . ( b ) Appliances . See ...
... CHIMNEYS , VENTS AND FIREPLACES Sec . 3701. ( a ) Scope . Chimneys , fireplaces , flues and vents carrying products of combusion , and their connections , shall conform to the requirements of this chapter . ( b ) Appliances . See ...
Page 274
... chimney as specified in Section 3704 . When a chimney with a cross - sectional area over 50 per cent larger than the cross - sectional area of the vent connec- tions to the chimney , is used as a vent , the chimney shall contain a gas ...
... chimney as specified in Section 3704 . When a chimney with a cross - sectional area over 50 per cent larger than the cross - sectional area of the vent connec- tions to the chimney , is used as a vent , the chimney shall contain a gas ...
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood