Uniform Building CodePacific Coast Building Officials Conference, 1946 - Building laws |
From inside the book
Results 1-3 of 24
Page 19
... comply with the provisions for new buildings and structures except as other- wise provided in Sections 104 , 306 , and 502 of this Code . Where , in any specific case , different sections of this Code specify different materials ...
... comply with the provisions for new buildings and structures except as other- wise provided in Sections 104 , 306 , and 502 of this Code . Where , in any specific case , different sections of this Code specify different materials ...
Page 20
... comply with the provisions of this Code . Buildings or structures moved into or within a Fire Zone shall comply with the provisions of Section 1601 ( c ) . ( i ) Maintenance . All buildings or structures both existing and new , and all ...
... comply with the provisions of this Code . Buildings or structures moved into or within a Fire Zone shall comply with the provisions of Section 1601 ( c ) . ( i ) Maintenance . All buildings or structures both existing and new , and all ...
Page 272
... comply with United States Bureau of Stand- ards Commercial Standard CS113-44 , " Oil - Burning Floor Fur- naces ... comply with A.S.A. “ Ap- proval Requirements for Gas - Fired Duct Furnaces , " ( Z21.34- 1942 ) . Gas floor furnaces ...
... comply with United States Bureau of Stand- ards Commercial Standard CS113-44 , " Oil - Burning Floor Fur- naces ... comply with A.S.A. “ Ap- proval Requirements for Gas - Fired Duct Furnaces , " ( Z21.34- 1942 ) . Gas floor furnaces ...
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood