Uniform Building CodePacific Coast Building Officials Conference, 1946 - Building laws |
From inside the book
Results 1-3 of 25
Page 94
... compressive strength of the brick used with grout and Type B mortar , but such assumed compressive strength shall not exceed a value of 2,000 pounds per square inch or 1,500 pounds per square inch respectively . Tests made to determine ...
... compressive strength of the brick used with grout and Type B mortar , but such assumed compressive strength shall not exceed a value of 2,000 pounds per square inch or 1,500 pounds per square inch respectively . Tests made to determine ...
Page 118
... stress grades , the compressive strength of the lowest stress grade shall govern . The allowable compressive stress perpendicular to the grain shall be the same for glued laminated lumber as for solid lumber of the same stress grade ...
... stress grades , the compressive strength of the lowest stress grade shall govern . The allowable compressive stress perpendicular to the grain shall be the same for glued laminated lumber as for solid lumber of the same stress grade ...
Page 124
... STRENGTH OF CONCRETE MIXTURES Proportions and Consistency Water - Content U. S. Gallons Per 94 - lb . Sack of Cement Assumed Compressive Strength at 28 Days U.S. Gallons Cu . Ft . p . s . i . 72 64 1.00 2000 .90 2500 .80 3000 .67 3750 6 ...
... STRENGTH OF CONCRETE MIXTURES Proportions and Consistency Water - Content U. S. Gallons Per 94 - lb . Sack of Cement Assumed Compressive Strength at 28 Days U.S. Gallons Cu . Ft . p . s . i . 72 64 1.00 2000 .90 2500 .80 3000 .67 3750 6 ...
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood