Page 126
drains to a sump , or be removed by other approved methods which will avoid
washing the freshly deposited concrete . Water vent pipes and drains shall be
filled by grouting or otherwise , after the concrete has hardened thoroughly .
drains to a sump , or be removed by other approved methods which will avoid
washing the freshly deposited concrete . Water vent pipes and drains shall be
filled by grouting or otherwise , after the concrete has hardened thoroughly .
Page 160
The term “ Composite Beam ” shall apply to any rolled or fabricated steel floor
beam entirely encased in poured concrete at least four inches ( 4 " ) wider , at its
narrowest point , than the flange of the beam , supporting a concrete slab on
each ...
The term “ Composite Beam ” shall apply to any rolled or fabricated steel floor
beam entirely encased in poured concrete at least four inches ( 4 " ) wider , at its
narrowest point , than the flange of the beam , supporting a concrete slab on
each ...
Page 232
Grade A concrete 2 2 112 1 Grade B concrete 3 212 2 112 Pneumatically placed
2 142 1 34 concrete Brick of clay , shale , con - 33 % 33 Steel or Cast Iron Col -
crete or sand - lin . e 214 114 umns ; Projecting Steel Clay tile , clay tile and
Beam ...
Grade A concrete 2 2 112 1 Grade B concrete 3 212 2 112 Pneumatically placed
2 142 1 34 concrete Brick of clay , shale , con - 33 % 33 Steel or Cast Iron Col -
crete or sand - lin . e 214 114 umns ; Projecting Steel Clay tile , clay tile and
Beam ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Page | 11 |
FireProtection of Structural Members 2210 Floor Construction | 12 |
Special Hazards | 13 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent allowable applied approved bars beams bearing bending bolts Building Official building or structure carry ceiling cement cent Chapter Class coat Code column compression concrete conform connections construction covering Definition designed diameter direction distance doors edge enclosures exceed exit extend exterior walls face feet fire fire-resistive construction floor foot foundation four frame grade Group gypsum height horizontal inches installed interior joints joists lath least length less load located masonry materials metal occupancy one-half openings panel partitions permit piles pipe placed plaster plate portion pounds protected reinforcement resistance rivets roof Separation shear side slab solid space span Special specified specified in Section square inch Standard steel story strength stress strip structural surface Table tests thickness tion Type unit values vent Ventilation vertical walls width wire wood