Uniform Building CodePacific Coast Building Officials Conference, 1946 - Building laws |
From inside the book
Results 1-3 of 44
Page 210
... connection with solid or liquid fuel shall be smaller in area than the flue connection on the appliance attached thereto , and in no case shall be less than as set forth in Table No. 37 - A . ( d ) Height . Every chimney shall extend to ...
... connection with solid or liquid fuel shall be smaller in area than the flue connection on the appliance attached thereto , and in no case shall be less than as set forth in Table No. 37 - A . ( d ) Height . Every chimney shall extend to ...
Page 213
... connection plus 50 per cent of the areas of all addi- tional connections with a minimum area of not less than twelve square inches ( 12 sq . in . ) and a minimum dimension of not less than two inches ( 2 " ) . ( d ) Connection Inlet ...
... connection plus 50 per cent of the areas of all addi- tional connections with a minimum area of not less than twelve square inches ( 12 sq . in . ) and a minimum dimension of not less than two inches ( 2 " ) . ( d ) Connection Inlet ...
Page 217
... connections and such sign shall read : " CONNECTION TO DRY STANDPIPE . " Sec . 3805. Every Group A , B and C occupancy of any height Wet and every Group D , E , F , G and H occupancy three or more Standpipes ; stories in height and ...
... connections and such sign shall read : " CONNECTION TO DRY STANDPIPE . " Sec . 3805. Every Group A , B and C occupancy of any height Wet and every Group D , E , F , G and H occupancy three or more Standpipes ; stories in height and ...
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood