Uniform Building CodePacific Coast Building Officials Conference, 1946 - Building laws |
From inside the book
Results 1-3 of 90
Page 64
... Construction PART V REQUIREMENTS BASED ON TYPES OF CONSTRUCTION - CHAPTER 17 CLASSIFICATION OF ALL BUILDINGS BY TYPES OF CONSTRUCTION AND GENERAL REQUIREMENTS Sec . 1701. The requirements of Part V are the minimum re- quirements for the ...
... Construction PART V REQUIREMENTS BASED ON TYPES OF CONSTRUCTION - CHAPTER 17 CLASSIFICATION OF ALL BUILDINGS BY TYPES OF CONSTRUCTION AND GENERAL REQUIREMENTS Sec . 1701. The requirements of Part V are the minimum re- quirements for the ...
Page 68
... Construction Stair Construction Doors and Windows not less than three - hour fire - resistive protection , for all build- ings more than eight stories or eighty ... Construction Roof Deck Construction Stair Construction Doors and Windows.
... Construction Stair Construction Doors and Windows not less than three - hour fire - resistive protection , for all build- ings more than eight stories or eighty ... Construction Roof Deck Construction Stair Construction Doors and Windows.
Page 236
... Construction ( Cont'd . ) Four - hour , three - hour and two - hour fire - resistive floors as specified in this Section shall be constructed entirely of incom- bustible materials . ( a ) Four - Hour . Four - hour fire - resistive floor ...
... Construction ( Cont'd . ) Four - hour , three - hour and two - hour fire - resistive floors as specified in this Section shall be constructed entirely of incom- bustible materials . ( a ) Four - Hour . Four - hour fire - resistive floor ...
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood