Uniform Building CodePacific Coast Building Officials Conference, 1946 - Building laws |
From inside the book
Results 1-3 of 32
Page 138
... Continuous edge .033 .040 .048 Discontinuous edge .055 .063 .083 .033 Positive Moment at Midspan .025 .030 .036 .041 .047 .062 .025 Case 2 - One Edge Discontinuous Negative Moment at Continuous edge .041 .048 Discontinuous edge .055 ...
... Continuous edge .033 .040 .048 Discontinuous edge .055 .063 .083 .033 Positive Moment at Midspan .025 .030 .036 .041 .047 .062 .025 Case 2 - One Edge Discontinuous Negative Moment at Continuous edge .041 .048 Discontinuous edge .055 ...
Page 142
... continuous with the positive reinforcement or anchored in a region of compression . Of the positive reinforcement in continuous beams not less than one - fourth the area shall extend along the same face of the beam into the support a ...
... continuous with the positive reinforcement or anchored in a region of compression . Of the positive reinforcement in continuous beams not less than one - fourth the area shall extend along the same face of the beam into the support a ...
Page 256
... Continuous Inspection . If continuous inspection is re- quired for certain materials where construction takes place on the site , it shall also be required where the same materials are used in prefabricated construction . Exception : ...
... Continuous Inspection . If continuous inspection is re- quired for certain materials where construction takes place on the site , it shall also be required where the same materials are used in prefabricated construction . Exception : ...
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood