Uniform Building CodePacific Coast Building Officials Conference, 1946 - Building laws |
From inside the book
Results 1-3 of 51
Page 72
... covered with one inch ( 1 ′′ ) nominal tongued and grooved top flooring laid crosswise and diagonally , or shall be an incombustible floor system of not less than one - hour fire- resistive construction . Roof Deck Construction Stair ...
... covered with one inch ( 1 ′′ ) nominal tongued and grooved top flooring laid crosswise and diagonally , or shall be an incombustible floor system of not less than one - hour fire- resistive construction . Roof Deck Construction Stair ...
Page 80
... covered on the outside with the materials and in the manner specified in this Section . 2. Weatherboarding . Studs or sheathing shall be covered on the outside face with one layer of building paper as specified in Section 2217 ...
... covered on the outside with the materials and in the manner specified in this Section . 2. Weatherboarding . Studs or sheathing shall be covered on the outside face with one layer of building paper as specified in Section 2217 ...
Page 274
... covering of No. 24 U. S. Gauge galvanized iron , furred with metal furring not less than one and one - half inches ( 11⁄2 " ) from such combustible construc- tion , or shall be entirely covered with one - hour fire - resistive ...
... covering of No. 24 U. S. Gauge galvanized iron , furred with metal furring not less than one and one - half inches ( 11⁄2 " ) from such combustible construc- tion , or shall be entirely covered with one - hour fire - resistive ...
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood