Uniform Building CodePacific Coast Building Officials Conference, 1946 - Building laws |
From inside the book
Results 1-3 of 48
Page 20
... Covering . Not more than 25 per cent of the roof covering of any building or structure shall be replaced in any 12 - month period unless the new roof covering is made to conform to the requirements of this Code for new buildings or ...
... Covering . Not more than 25 per cent of the roof covering of any building or structure shall be replaced in any 12 - month period unless the new roof covering is made to conform to the requirements of this Code for new buildings or ...
Page 80
... Coverings Wall Coverings Foundation walls and all other walls used as retaining walls in connection with Type V ... covering provided the frame of the structure is covered with building paper as specified in Section 2217. The 80 ...
... Coverings Wall Coverings Foundation walls and all other walls used as retaining walls in connection with Type V ... covering provided the frame of the structure is covered with building paper as specified in Section 2217. The 80 ...
Page 236
... covering of not less than two inches ( 2 " ) of solid masonry , or shall consist of steel joists or steel floors protected with fire - resistive materials of the kind and thickness set forth in Table No. 43 - C . Except in the case of ...
... covering of not less than two inches ( 2 " ) of solid masonry , or shall consist of steel joists or steel floors protected with fire - resistive materials of the kind and thickness set forth in Table No. 43 - C . Except in the case of ...
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood