Uniform Building CodePacific Coast Building Officials Conference, 1946 - Building laws |
From inside the book
Results 1-3 of 68
Page 6
... Defined Construction , Height and Area Allowable 703. Location on Property 704 . Exit Facilities 705. Light , Ventilation , and Sanitation Enclosure of Vertical Openings 706 . 707. Fire - Extinguishing Apparatus 708. Special Hazards 709 ...
... Defined Construction , Height and Area Allowable 703. Location on Property 704 . Exit Facilities 705. Light , Ventilation , and Sanitation Enclosure of Vertical Openings 706 . 707. Fire - Extinguishing Apparatus 708. Special Hazards 709 ...
Page 7
... Defined Construction , Height and Area Allowable 1103. Location on Property 1104 . Exit Facilities 1105. Light , Ventilation , and Sanitation 1106. Enclosure of Vertical Openings 1107. Fire - Extinguishing Apparatus 1108 . CHAPTER 12 ...
... Defined Construction , Height and Area Allowable 1103. Location on Property 1104 . Exit Facilities 1105. Light , Ventilation , and Sanitation 1106. Enclosure of Vertical Openings 1107. Fire - Extinguishing Apparatus 1108 . CHAPTER 12 ...
Page 107
... Definition of Seasoned Lumber . " Seasoned lumber " for the purpose of this Section , is defined as lumber which has been air - dried for at least 60 days , or which has at the time of installation in the structure reached a moisture ...
... Definition of Seasoned Lumber . " Seasoned lumber " for the purpose of this Section , is defined as lumber which has been air - dried for at least 60 days , or which has at the time of installation in the structure reached a moisture ...
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood