Uniform Building CodePacific Coast Building Officials Conference, 1946 - Building laws |
From inside the book
Results 1-3 of 35
Page 136
Reinforcement for shrinkage and temperature Temperature stresses normal to
the principal reinforcement shall be provided Reinforcement in floor and roof
slabs where the principal reinforcement extends in one direction only .
Reinforcement for shrinkage and temperature Temperature stresses normal to
the principal reinforcement shall be provided Reinforcement in floor and roof
slabs where the principal reinforcement extends in one direction only .
Page 144
The term flat slabs as used in these regulations refers to concrete slabs ,
generally without beams or girders to carry the load to supporting members ,
reinforced with bars extending in two or four directions . Slabs with dropped
panels or ...
The term flat slabs as used in these regulations refers to concrete slabs ,
generally without beams or girders to carry the load to supporting members ,
reinforced with bars extending in two or four directions . Slabs with dropped
panels or ...
Page 265
International Conference of Building Officials, Pacific Coast Building Officials
Conference. TABLE NO . 23 - A - HORIZONTAL FORCE FACTORS Direction of
Force Part or Portion Value of “ C ” * The structure as a whole . 02 on soil , and
every ...
International Conference of Building Officials, Pacific Coast Building Officials
Conference. TABLE NO . 23 - A - HORIZONTAL FORCE FACTORS Direction of
Force Part or Portion Value of “ C ” * The structure as a whole . 02 on soil , and
every ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Page | 11 |
FireProtection of Structural Members 2210 Floor Construction | 12 |
Special Hazards | 13 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent allowable applied approved bars beams bearing bending bolts Building Official building or structure carry ceiling cement cent Chapter Class coat Code column compression concrete conform connections construction covering Definition designed diameter direction distance doors edge enclosures exceed exit extend exterior walls face feet fire fire-resistive construction floor foot foundation four frame grade Group gypsum height horizontal inches installed interior joints joists lath least length less load located masonry materials metal occupancy one-half openings panel partitions permit piles pipe placed plaster plate portion pounds protected reinforcement resistance rivets roof Separation shear side slab solid space span Special specified specified in Section square inch Standard steel story strength stress strip structural surface Table tests thickness tion Type unit values vent Ventilation vertical walls width wire wood