Page 201
... Discharge Areas . A horizontal exit shall lead into a floor area having capacity for an occupant load not less than the occupant load served by such exit . The capacity shall be determined by allowing three square feet ( 3 sq . ft ...
... Discharge Areas . A horizontal exit shall lead into a floor area having capacity for an occupant load not less than the occupant load served by such exit . The capacity shall be determined by allowing three square feet ( 3 sq . ft ...
Page 202
... Discharge . Every exit court shall discharge into a public way or passageway leading to a public way . The passageway shall be without other openings and shall have walls , floors , and ceilings of the same period of fire resistance as ...
... Discharge . Every exit court shall discharge into a public way or passageway leading to a public way . The passageway shall be without other openings and shall have walls , floors , and ceilings of the same period of fire resistance as ...
Page 299
... discharge for exit courts . As horizontal exits ......... 4302 2521 ..2404 ( c ) , 2620 ( 1 ) , 2715 , 4704 401 3311 3307 3308 ( d ) 3309 ( f ) 3801 As stairway enclosures .. For smokeproof enclosures . To be sprinklered , when ...
... discharge for exit courts . As horizontal exits ......... 4302 2521 ..2404 ( c ) , 2620 ( 1 ) , 2715 , 4704 401 3311 3307 3308 ( d ) 3309 ( f ) 3801 As stairway enclosures .. For smokeproof enclosures . To be sprinklered , when ...
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood