Uniform Building CodePacific Coast Building Officials Conference, 1946 - Building laws |
From inside the book
Results 1-3 of 23
Page 32
... ENCLOSED , is a partially enclosed portion of an assembly room the ceiling of which is not more than five feet ( 5 ' ) above the proscenium opening and which is designed or used for the presentation of plays , demonstrations , or other ...
... ENCLOSED , is a partially enclosed portion of an assembly room the ceiling of which is not more than five feet ( 5 ' ) above the proscenium opening and which is designed or used for the presentation of plays , demonstrations , or other ...
Page 54
... enclosed as specified in Chapter 33 . Other vertical openings are not required to be enclosed . Sec . 1207. Automatic sprinklers , standpipes and basement pipe inlets shall be installed as specified in Chapter 38 . Sec . 1208. Chimneys ...
... enclosed as specified in Chapter 33 . Other vertical openings are not required to be enclosed . Sec . 1207. Automatic sprinklers , standpipes and basement pipe inlets shall be installed as specified in Chapter 38 . Sec . 1208. Chimneys ...
Page 221
... enclosed platform having a floor area of five hundred square feet ( 500 sq . ft . ) or more . ( b ) Construction . Walls and ceiling of an enclosed plat- form in an assembly room shall be of not less than one - hour fire - resistive ...
... enclosed platform having a floor area of five hundred square feet ( 500 sq . ft . ) or more . ( b ) Construction . Walls and ceiling of an enclosed plat- form in an assembly room shall be of not less than one - hour fire - resistive ...
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood