... Enclosures for elevator shafts , vent shafts , and Enclosure of other vertical openings when required because of occupancy in Vertical Part III shall be of not less than two - hour fire - resistive con- Openings struction ( see Chapter ...
... Enclosures for elevator shafts , vent shafts , and Enclosure of other vertical openings when required because of occupancy in Vertical Part III shall be of not less than two - hour fire - resistive con- Openings struction ( see Chapter ...
Page 201
... enclosures are not required for escalators . 3. Stairs in Group I occupancies need not be enclosed . ( b ) Enclosure Construction . Enclosure walls shall be of not less than two - hour fire - resistive construction in buildings more ...
... enclosures are not required for escalators . 3. Stairs in Group I occupancies need not be enclosed . ( b ) Enclosure Construction . Enclosure walls shall be of not less than two - hour fire - resistive construction in buildings more ...
Page 202
... enclosure shall be protected by a Class " E " or " F " fire door or window unless opening into a public way at least sixteen feet ( 16 ' ) wide . ( d ) Extent of Enclosure . Stairway enclosures shall include the necessary landings ...
... enclosure shall be protected by a Class " E " or " F " fire door or window unless opening into a public way at least sixteen feet ( 16 ' ) wide . ( d ) Extent of Enclosure . Stairway enclosures shall include the necessary landings ...
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood