Uniform Building CodePacific Coast Building Officials Conference, 1946 - Building laws |
From inside the book
Results 1-3 of 84
Page 70
... feet ( 75 ' ) ; provided , that the height of a building erected on sloping ground may be seventy - five feet ( 75 ' ) plus a vertical distance equal to the vertical change in slope along the length of any side of such building but in ...
... feet ( 75 ' ) ; provided , that the height of a building erected on sloping ground may be seventy - five feet ( 75 ' ) plus a vertical distance equal to the vertical change in slope along the length of any side of such building but in ...
Page 74
... feet ( 55 ' ) ; provided , that the height of a building erected on sloping ground may be fifty - five feet ( 55 ' ) plus a vertical distance equal to the vertical change in slope along and in the length of any side of such building ...
... feet ( 55 ' ) ; provided , that the height of a building erected on sloping ground may be fifty - five feet ( 55 ' ) plus a vertical distance equal to the vertical change in slope along and in the length of any side of such building ...
Page 242
... feet or less DISTANCE FROM CONSTRUCTION TO WALKWAY Less than six feet PROTECTION REQUIRED Railing More than eight feet Six feet or more None Less than six feet Six feet or more and one - quarter height of construction or less Six feet ...
... feet or less DISTANCE FROM CONSTRUCTION TO WALKWAY Less than six feet PROTECTION REQUIRED Railing More than eight feet Six feet or more None Less than six feet Six feet or more and one - quarter height of construction or less Six feet ...
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood