Uniform Building CodePacific Coast Building Officials Conference, 1946 - Building laws |
From inside the book
Results 1-3 of 25
Page 250
... Finish Coats for Gypsum or Lime Plaster . The finish coats shall be mixed and proportioned in accordance with the following procedure : 1. Smooth white finish , mixed in the proportion of not less than one part gypsum gauging plaster or ...
... Finish Coats for Gypsum or Lime Plaster . The finish coats shall be mixed and proportioned in accordance with the following procedure : 1. Smooth white finish , mixed in the proportion of not less than one part gypsum gauging plaster or ...
Page 251
... finish , mixed in the proportions of three parts Keene's cement to one part lime putty , by volume . 5. Lime sand - float finish shall be mixed in the proportion of one part gypsum gauging plaster or Keene's cement , three parts of lime ...
... finish , mixed in the proportions of three parts Keene's cement to one part lime putty , by volume . 5. Lime sand - float finish shall be mixed in the proportion of one part gypsum gauging plaster or Keene's cement , three parts of lime ...
Page 253
... finish 2 ** 18 " * Measured from backing to crest of scored plaster . ** Approved prepared finish coats containing not less than 1/3 by weight of port- land cement may be used . the studs and horizontal joints where expanded metal or ...
... finish 2 ** 18 " * Measured from backing to crest of scored plaster . ** Approved prepared finish coats containing not less than 1/3 by weight of port- land cement may be used . the studs and horizontal joints where expanded metal or ...
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood