( a ) Fire Zones Defined . For the purpose of this General Code , the entire city is
hereby declared to be and is hereby established a Fire District and said Fire
District shall be known and designated as Fire Zones One , Two and Three , and
shall ...
( a ) Fire Zones Defined . For the purpose of this General Code , the entire city is
hereby declared to be and is hereby established a Fire District and said Fire
District shall be known and designated as Fire Zones One , Two and Three , and
shall ...
Page 238
Fire - Resistive required in Sections 603 , 608 , 703 , 708 , 803 , 808 , 903 , 1003 ,
Assemblies for 1008 , 1103 , 1303 , 1602 ( c ) , 1807 , 1813 , 1815 , 1913 , 3305 (
h ) , Protection 3308 ( c ) , 3311 ( d ) , and 3316 . of Openings Fire doors and ...
Fire - Resistive required in Sections 603 , 608 , 703 , 708 , 803 , 808 , 903 , 1003 ,
Assemblies for 1008 , 1103 , 1303 , 1602 ( c ) , 1807 , 1813 , 1815 , 1913 , 3305 (
h ) , Protection 3308 ( c ) , 3311 ( d ) , and 3316 . of Openings Fire doors and ...
Page 239
International Conference of Building Officials, Pacific Coast Building Officials
Conference. ( i ) Glass . Glass used in fire doors or fire windows shall be not less
than one - fourth inch ( 14 " ) thick and shall be reinforced with wire mesh , 24
gauge ...
International Conference of Building Officials, Pacific Coast Building Officials
Conference. ( i ) Glass . Glass used in fire doors or fire windows shall be not less
than one - fourth inch ( 14 " ) thick and shall be reinforced with wire mesh , 24
gauge ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Page | 11 |
FireProtection of Structural Members 2210 Floor Construction | 12 |
Special Hazards | 13 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent allowable applied approved bars beams bearing bending bolts Building Official building or structure carry ceiling cement cent Chapter Class coat Code column compression concrete conform connections construction covering Definition designed diameter direction distance doors edge enclosures exceed exit extend exterior walls face feet fire fire-resistive construction floor foot foundation four frame grade Group gypsum height horizontal inches installed interior joints joists lath least length less load located masonry materials metal occupancy one-half openings panel partitions permit piles pipe placed plaster plate portion pounds protected reinforcement resistance rivets roof Separation shear side slab solid space span Special specified specified in Section square inch Standard steel story strength stress strip structural surface Table tests thickness tion Type unit values vent Ventilation vertical walls width wire wood