... FIRE ZONES CHAPTER 16 - RESTRICTIONS IN FIRE ZONES Sec . 1601. ( a ) Fire Zones Defined . For the purpose of this General Code , the entire city is hereby declared to be and is hereby established a Fire District and said Fire District ...
... FIRE ZONES CHAPTER 16 - RESTRICTIONS IN FIRE ZONES Sec . 1601. ( a ) Fire Zones Defined . For the purpose of this General Code , the entire city is hereby declared to be and is hereby established a Fire District and said Fire District ...
Page 238
... Fire doors and windows are not required in fire - resistive walls or partitions unless specified elsewhere in this Code . ( b ) Scope . Fire doors and windows wherever specified in this Code shall meet the requirements of this Section ...
... Fire doors and windows are not required in fire - resistive walls or partitions unless specified elsewhere in this Code . ( b ) Scope . Fire doors and windows wherever specified in this Code shall meet the requirements of this Section ...
Page 239
... fire doors or fire windows shall be not less than one - fourth inch ( 4 " ) thick and shall be rein- forced with wire mesh , 24 gauge or heavier , with openings not larger than one inch ( 1 " ) square . Glass shall be held in place by ...
... fire doors or fire windows shall be not less than one - fourth inch ( 4 " ) thick and shall be rein- forced with wire mesh , 24 gauge or heavier , with openings not larger than one inch ( 1 " ) square . Glass shall be held in place by ...
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood