Page 64
The various Types of Construction herein defined represent varying degrees of
public safety and resistance to fire . Where specific materials , types of
construction or fire - resistive protection are required , such requirements shall be
the ...
The various Types of Construction herein defined represent varying degrees of
public safety and resistance to fire . Where specific materials , types of
construction or fire - resistive protection are required , such requirements shall be
the ...
Page 66
The exterior walls , inner court walls , and walls enclosing vertical openings ,
shall be of fire - resistive construction . The roof construction and floors shall be of
fireresistive materials . Exterior doors and windows , except as specified in
Section ...
The exterior walls , inner court walls , and walls enclosing vertical openings ,
shall be of fire - resistive construction . The roof construction and floors shall be of
fireresistive materials . Exterior doors and windows , except as specified in
Section ...
Page 236
Fire - Resistive Floor , Roof and Ceiling Construction ( Cont ' d . ) Four - hour ,
three - hour and two - hour fire - resistive floors as specified in this Section shall
be constructed entirely of incombustible materials . ( a ) Four - Hour . Four - hour
fire ...
Fire - Resistive Floor , Roof and Ceiling Construction ( Cont ' d . ) Four - hour ,
three - hour and two - hour fire - resistive floors as specified in this Section shall
be constructed entirely of incombustible materials . ( a ) Four - Hour . Four - hour
fire ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Page | 11 |
FireProtection of Structural Members 2210 Floor Construction | 12 |
Special Hazards | 13 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent allowable applied approved bars beams bearing bending bolts Building Official building or structure carry ceiling cement cent Chapter Class coat Code column compression concrete conform connections construction covering Definition designed diameter direction distance doors edge enclosures exceed exit extend exterior walls face feet fire fire-resistive construction floor foot foundation four frame grade Group gypsum height horizontal inches installed interior joints joists lath least length less load located masonry materials metal occupancy one-half openings panel partitions permit piles pipe placed plaster plate portion pounds protected reinforcement resistance rivets roof Separation shear side slab solid space span Special specified specified in Section square inch Standard steel story strength stress strip structural surface Table tests thickness tion Type unit values vent Ventilation vertical walls width wire wood