Floor Sec . 1810 . Floor construction shall consist of any incomConstruction
bustible floor system of not less than three - hour fire - resistive construction for all
buildings housing Group E occupancies more than eight stories or eighty - five
feet ...
Floor Sec . 1810 . Floor construction shall consist of any incomConstruction
bustible floor system of not less than three - hour fire - resistive construction for all
buildings housing Group E occupancies more than eight stories or eighty - five
feet ...
Page 85
A reduction of the total live load used in the design of girders based on a certain
tributary floor area shall be permitted as noted in the following schedule . This
reduction shall not be carried into the columns nor shall such reduction be used
in ...
A reduction of the total live load used in the design of girders based on a certain
tributary floor area shall be permitted as noted in the following schedule . This
reduction shall not be carried into the columns nor shall such reduction be used
in ...
Page 236
Fire - Resistive Floor , Roof and Ceiling Construction ( Cont ' d . ) Four - hour ,
three - hour and two - hour fire - resistive floors as specified in this Section shall
be constructed entirely of incombustible materials . ( a ) Four - Hour . Four - hour
fire ...
Fire - Resistive Floor , Roof and Ceiling Construction ( Cont ' d . ) Four - hour ,
three - hour and two - hour fire - resistive floors as specified in this Section shall
be constructed entirely of incombustible materials . ( a ) Four - Hour . Four - hour
fire ...
What people are saying - Write a review
We haven't found any reviews in the usual places.
Contents
Page | 11 |
FireProtection of Structural Members 2210 Floor Construction | 12 |
Special Hazards | 13 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent allowable applied approved bars beams bearing bending bolts Building Official building or structure carry ceiling cement cent Chapter Class coat Code column compression concrete conform connections construction covering Definition designed diameter direction distance doors edge enclosures exceed exit extend exterior walls face feet fire fire-resistive construction floor foot foundation four frame grade Group gypsum height horizontal inches installed interior joints joists lath least length less load located masonry materials metal occupancy one-half openings panel partitions permit piles pipe placed plaster plate portion pounds protected reinforcement resistance rivets roof Separation shear side slab solid space span Special specified specified in Section square inch Standard steel story strength stress strip structural surface Table tests thickness tion Type unit values vent Ventilation vertical walls width wire wood