... floors , joists and slabs shall be thoroughly fire - protected with not less than two - hour fire - resistive protection for all other buildings . Sec . 1810. Floor construction shall consist of any incom- bustible floor system of not ...
... floors , joists and slabs shall be thoroughly fire - protected with not less than two - hour fire - resistive protection for all other buildings . Sec . 1810. Floor construction shall consist of any incom- bustible floor system of not ...
Page 85
... floor area shall be per- mitted as noted in the following schedule . This reduction shall not be carried into the columns nor shall such reduction be used in design of buildings to be used or occupied as warehouses or for storage ...
... floor area shall be per- mitted as noted in the following schedule . This reduction shall not be carried into the columns nor shall such reduction be used in design of buildings to be used or occupied as warehouses or for storage ...
Page 236
... floors as specified in this Section shall be constructed entirely of incom- bustible materials . ( a ) Four - Hour . Four - hour fire - resistive floor construction shall consist of concrete , gypsum or solid masonry slabs or arches not ...
... floors as specified in this Section shall be constructed entirely of incom- bustible materials . ( a ) Four - Hour . Four - hour fire - resistive floor construction shall consist of concrete , gypsum or solid masonry slabs or arches not ...
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood