Uniform Building CodePacific Coast Building Officials Conference, 1946 - Building laws |
From inside the book
Results 1-3 of 98
Page 50
... Floor Area per Story Allowable floor area per story is also includ- ed in Table 503 for the five construction types and 10 occupancy groups . These are designat- ed by the letter A in the second column in the second row in each ...
... Floor Area per Story Allowable floor area per story is also includ- ed in Table 503 for the five construction types and 10 occupancy groups . These are designat- ed by the letter A in the second column in the second row in each ...
Page 209
... floor area 358 Treated floor area 54 Treated floor area 85 Treated floor area ?? Gross floor area and dental practices ) Public buildings ambulance stations 70 churches courts ( Magistrates ) courts ( County ) courts ( Crown ) courts ...
... floor area 358 Treated floor area 54 Treated floor area 85 Treated floor area ?? Gross floor area and dental practices ) Public buildings ambulance stations 70 churches courts ( Magistrates ) courts ( County ) courts ( Crown ) courts ...
Page
... area of glazing in the most glazed room Maximum area Maximum of orientation glazing in the glazing (% floor area) (% floor area of room) glazing (% glazed room (% floor area) area of room) area area of most floor With cross-ventilation ...
... area of glazing in the most glazed room Maximum area Maximum of orientation glazing in the glazing (% floor area) (% floor area of room) glazing (% glazed room (% floor area) area of room) area area of most floor With cross-ventilation ...
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood