Uniform Building CodePacific Coast Building Officials Conference, 1946 - Building laws |
From inside the book
Results 1-3 of 71
Page 37
... space on the lot on which a building is located , permanently maintained as an integral part thereof , and free of all obstruction from the ground up . ( b ) One - Story Areas . The area of a one - story building shall not exceed the ...
... space on the lot on which a building is located , permanently maintained as an integral part thereof , and free of all obstruction from the ground up . ( b ) One - Story Areas . The area of a one - story building shall not exceed the ...
Page 60
Pacific Coast Building Officials Conference, International Conference of Building Officials. Group J Occupancies Defined Construction , Height and Area Allowable Location on Property Exit Facilities Light and Ventilation Enclosure of ...
Pacific Coast Building Officials Conference, International Conference of Building Officials. Group J Occupancies Defined Construction , Height and Area Allowable Location on Property Exit Facilities Light and Ventilation Enclosure of ...
Page 85
... floor area shall be per- mitted as noted in the following schedule . This reduction shall not be carried into the columns nor shall such reduction be used in design of buildings to be used or occupied as warehouses or for storage ...
... floor area shall be per- mitted as noted in the following schedule . This reduction shall not be carried into the columns nor shall such reduction be used in design of buildings to be used or occupied as warehouses or for storage ...
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood