Uniform Building CodePacific Coast Building Officials Conference, 1946 - Building laws |
From inside the book
Results 1-3 of 81
Page 91
... four feet ( 4 ' ) ( Cont'd . ) horizontally and shall have at least eight inches ( 8 " ) of masonry in back of the chases and between chases and jambs of openings , provided that in dwellings not over two stories high , chases not over four ...
... four feet ( 4 ' ) ( Cont'd . ) horizontally and shall have at least eight inches ( 8 " ) of masonry in back of the chases and between chases and jambs of openings , provided that in dwellings not over two stories high , chases not over four ...
Page 113
... four feet ( 4 ′ ) . ( c ) Bridging . All stud partitions or walls over ten feet ( 10 ′ ) in height shall have ... four - inch ( 2 " x4 " ) studs ; for buildings of three stories . the studding shall be not less than three - inch by four ...
... four feet ( 4 ′ ) . ( c ) Bridging . All stud partitions or walls over ten feet ( 10 ′ ) in height shall have ... four - inch ( 2 " x4 " ) studs ; for buildings of three stories . the studding shall be not less than three - inch by four ...
Page 236
... Four - hour , three - hour and two - hour fire - resistive floors as specified in this Section shall be constructed entirely of incom- bustible materials . ( a ) Four - Hour . Four - hour fire - resistive floor construction shall ...
... Four - hour , three - hour and two - hour fire - resistive floors as specified in this Section shall be constructed entirely of incom- bustible materials . ( a ) Four - Hour . Four - hour fire - resistive floor construction shall ...
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood