Uniform Building CodePacific Coast Building Officials Conference, 1946 - Building laws |
From inside the book
Results 1-3 of 30
Page 98
... gypsum shall not be used in any bearing wall or in any location where the gypsum is directly exposed to moisture or weathering . Precast reinforced gypsum shall contain not more than three per cent , and cast - in - place reinforced gypsum ...
... gypsum shall not be used in any bearing wall or in any location where the gypsum is directly exposed to moisture or weathering . Precast reinforced gypsum shall contain not more than three per cent , and cast - in - place reinforced gypsum ...
Page 232
... gypsum blocks 3 pl . 3 2 2 Poured gypsum Metal lath and gypsum or portland cement plaster Grade A concrete 2 12 1 1 ---- .... 22 * 1 2 112 1 1 Grade B concrete 3 22 12 1 Pneumatically placed 2 12 1 3/4 concrete Brick of clay , shale ...
... gypsum blocks 3 pl . 3 2 2 Poured gypsum Metal lath and gypsum or portland cement plaster Grade A concrete 2 12 1 1 ---- .... 22 * 1 2 112 1 1 Grade B concrete 3 22 12 1 Pneumatically placed 2 12 1 3/4 concrete Brick of clay , shale ...
Page 250
... gypsum or hardwall plaster to not more than three parts sand by weight . The second coat for all three - coat work shall be mixed in the proportion of one part of gypsum or hardwall plaster to not more than three parts of sand by weight ...
... gypsum or hardwall plaster to not more than three parts sand by weight . The second coat for all three - coat work shall be mixed in the proportion of one part of gypsum or hardwall plaster to not more than three parts of sand by weight ...
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood