Page 70
... incombustible materials . Floors and non - bearing partitions shall be of wood or incombustible materials . Concealed or inaccessi- ble spaces in combustible framing shall not be permitted . Sec . 1902. Type II buildings shall not ...
... incombustible materials . Floors and non - bearing partitions shall be of wood or incombustible materials . Concealed or inaccessi- ble spaces in combustible framing shall not be permitted . Sec . 1902. Type II buildings shall not ...
Page 77
... Incombustible Frame ) Sec . 2101. In " Type IV Buildings " the structural framework Definition shall be of steel , iron , masonry or concrete and exterior walls shall be of incombustible materials . Partitions , floors and roof ...
... Incombustible Frame ) Sec . 2101. In " Type IV Buildings " the structural framework Definition shall be of steel , iron , masonry or concrete and exterior walls shall be of incombustible materials . Partitions , floors and roof ...
Page 235
... Incombustible studding with metal or wire lath , neat wood fiber gypsum plaster . Incombustible studding with metal or wire lath . 34 - in . plaster on each side 3 * Shall be used for non - bearing purposes only . ** 8 in . for Expanded ...
... Incombustible studding with metal or wire lath , neat wood fiber gypsum plaster . Incombustible studding with metal or wire lath . 34 - in . plaster on each side 3 * Shall be used for non - bearing purposes only . ** 8 in . for Expanded ...
Contents
Page | 11 |
Part IAdministrative | 19 |
Part IIDefinitions and Abbreviations | 29 |
Copyright | |
21 other sections not shown
Other editions - View all
Common terms and phrases
adjacent property lines approved bars beams bending bolts Building Official building or structure ceiling cent Chimneys Code combustible material compression members compressive strength conform dead load designed diameter dry standpipes enclosures exceed exit exterior walls fire doors Fire Zone fire-protected flange foot frame furnace girders grade Group gypsum height horizontal incombustible installed interior joints joists least length less than one-hour live load located lumber metal minimum mortar Occupancy Separation one-half inch one-hour fire-resistive construction partitions permit pipe plaster portland cement pounds per square proscenium protected reinforced concrete resistance rivets shear side six inches smoke pipe space span specified in Chapter specified in Section square feet square inch stairway structural steel studs Table tensile stress tests thickness tile tion total band twelve inches 12 twenty feet 20 Type V buildings TYPES OF CONSTRUCTION unit stress vent Ventilation vertical openings width wood